Dynalec Controls

DCPL Software for interfacing

Specification of Dynamometer Controller :

  • Max. excitation current : Internally set, generally at 6A DC.
  • Fuse Protections : 6 A HRC type for excitation current 500 mA glass type for Controller
  • Display : 4 1/2″ digit, 7 segments, 0.5″ height LED
  • Range : 0 – 1000 Nm
  • Resolution : 0.1 Nm (Digital Indication)
  • Accuracy : 0.2 ± % FSD (Digital Indication)
  • Input Voltage Range : ± 30 mV max with initial offset of ± 5 mV
  • Excitation Voltage : 10 V ± 1 V DC
  • Tare adjustment : 5O % of full load capacity
  • Span : ± 5O % of load
  • Drift : ± 1 count / 10 °C approx.
  • Damping : A toggle switch is provided to select either 0.1 s or 1.5 s time constant.
  • Output : 0 to 10 VDC Analog – for full scale and Serial (RS485)

RPM INDICATION :

  • Display : 4 digits, 7 segments, 0.5″ height LED
  • Range : 0 – 9999 RPM
  • Resolution : 1 RPM (Digital Indication)
  • Accuracy : 1 RPM (Digital Indication)
  • Input : from Magnetic Pick- Up
  • Input sensitivity : 10 mV
  • Outputs : 0 to 10 VDC Analog (For maximum operating RPM) – Pulse – Serial (RS485)

  • ENVIRONMENTAL:

  • Operating Temp. : 0 C to 55 C maximum
  • Humidity : R.H. 95% maximum

Specification of Throttle Controller :

ELECTRICAL :
Supply Voltage : 220 V AC, 10 %,50 Hz, Single Phase
Fuse Protections : 300 mA glass type 100 mA for 2.5 & 5 VDC output
Display : Analog for 0 to 100 % throttle position
Output : 0 – 2.5 VDC for ECU
0 – 5.0 VDC for ECU
0 – 10.0 VDC for throttle position